Skip to content

RACK XR 1500W Programmable Power Supply 100V 20A with LAN, analog and USB

Save 5%
Original price €2.100,00
Current price €1.995,00

RACK XR 1500W Programmable Power Supply 100V-20A

The New Versatile Power RACK XR Series are economical, programmable, DC power supplies that will give you just the right performance at just the right price in a small, compact package.

Main features

  • 1500W with Extended Range
  • Small, High-Density 1U Package
  • The built-in OLED front panel simultaneously shows both voltage and current readings
  • Full Digital Control
  • Wireless Digital Remote Sense
  • Built-In Voltage and Current Measurement
  • Full OCP and OVP Protection
  • Standard Ethernet, USB 2.0 and Analog interfaces
  • Command Capability for Keysight 603x, Sorenson DLM and Xantrex XFR
  • SCPI Compliant USB with LabVIEW Driver

 

DATASHEET DOWNLOAD LINK

MANUAL DOWNLOAD LINK

 

SPECIFICATIONS

 

BENCH XR MODEL:   30-33 XR 50-20 XR    100-10 XR 200-5 XR 400-2.5 XR
Output1
Voltage, Volts                               30 V         50 V    100 V 200 V 400 V
Current, Amps                         33 A 20 A 10 A 5 A 2.5 A
Power, Watts    600 W 600 W 600 W 600 W 600 W
Output Ripple & Noise2
RMS Constant Voltage                   5 mV         5 mV        10 mV 25 mV 50 mV
P-P Constant Voltage                         20mV   25 mV       50 mV 100 mV 200 mV
Regulation
Load: 10-90% - Voltage                                          15 mV 25 mV 50 mV 100 mV 200 mV
Load: 10-90% - Current                                        15 mA 15 mA 15 mA 15 mA 15 mA
Line: 90-132 VAC Input  - Voltage2        15 mV 25 mV 50 mV 100 mV 200 mV
Line: 90-132 VAC Input  - Current2                15 mA 15 mA 15 mA 15 mA 15 mA
Line: 180-260 VAC Input  - Voltage2                               15 mV 25 mV 50 mV 100 mV 200 mV
Line: 180-260 VAC Input  - Current2                                    15 mA 15 mA 15 mA 15 mA 15 mA
Programming Accuracy1
Voltage (0.1%+) 15 mV 25 mV 50 mV 100 mV 200 mV
Current   (0.1%+)                                            15 mA 15 mA 15 mA 15 mA 15 mA
Measurement Accuracy
Voltage    (0.1%+)                                                 15 mV 25 mV 50 mV 100 mV 200 mV
Current      (0.1%+)                                                  15 mA 15 mA 15 mA 15 mA 15 mA
Transient Recovery Time3
Time  ≤1 ms
Supplemental Characteristics*
Output response time (settle to within ±1% of the rated output, with a resistive load)
Up, Full Load, Seconds 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s
Down, Full Load, Seconds  0.08 s 0.08 s 0.08 s 0.08 s 0.08 s
Down, No Load, Seconds    0.50 s 0.50 s 0.50 s 0.50 s 0.50 s
Command Response Time4, Milliseconds                                50 ms
Data Readback Transfer Time5, Milliseconds                              5 ms
Remote Sense Compensation Volts/Load Lead 1 V 1 V 2 V 4 V 4 V
Over-Voltage Protection
Range, Volts                                 0.5-33 V         0.5-55 V  0.5-110 V 0.5-220 V 0.5-440 V
Accuracy, Volts                                          0.3 V           0.5 V 1.0 V 2.0 V 14.0 V
Output Ripple and Noise , CC rms, Milliamps 7 mA 5 mA 5 mA 5 mA 10 mA
Programming Resolution Voltage  (0.05%+)                                   0.1% 10 mV 25 mV 50 mV 100 mV 200 mV
Measurement Resolution Current     (0.05%+)                                0.1% 20 mA 20 mA 10 mA 5 mA 2.5 mA
Front Panel Display Accuracy:
for Voltage  (0.1%+)                                                    10 mV 25 mV 50 mV 100 mV 200 mV
for Current  (0.1%+)                                                      33 mA 20 mA 10 mA 5 mA 2.5 mA
Mechanical
Dimensions             44 mm x 483 mm x 394 mm
Weight                                      5.8 Kg

 Notes
      1. Minimum voltage is guaranteed to a maximum of 1% of the rated output voltage. Minimum current is guaranteed to a maximum of 1% of the rated output current.
      2. Up to 20 MHz (see application note AN024 for measurement details).
      3. Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output.
      4. Add this to the output reopens time to obtain the total programming time.
      5. Time to provide data back to the controller using LAN interface (does not include A/D conversion time).
      * Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing.